Egress & Basement Windows in Ontario
The short answer
In Ontario, a bedroom egress window must open, without tools, to a clear area of at least 0.35 m² (about 3.8 sq ft), with no side of that opening smaller than 380 mm (about 15 in).
That is Article 9.9.10.1 of the Ontario Building Code. Every floor level with a bedroom needs at least one such window, unless a door on that level leads directly outside. If the window opens into a window well, the well needs at least 550 mm (about 22 in) of clearance in front of the window.
Ontario egress window requirements at a glance
| Requirement | Ontario Building Code minimum |
|---|---|
| Clear open area | 0.35 m² (about 3.8 sq ft), unobstructed |
| Smallest side of the opening | 380 mm (about 15 in), height or width |
| How it opens | From the inside, without tools, and it must stay open without a prop |
| Sill height | No more than 1,000 mm (about 39 in) above the floor; basements are exempt from this limit |
| Window well | At least 550 mm (about 22 in) of clearance in front of the window |
| Sliding windows | The 380 mm minimum applies to the part that actually opens |
From Article 9.9.10.1, Division B of Ontario's Building Code (O. Reg. 163/24). Imperial figures are rounded. Your municipal building department has the final say on your project.
What the Egress Rule Means in Practice
An egress window is an escape route. If a fire blocks the stairs, someone sleeping in a basement or upper bedroom needs a window they can open and climb through. The Code therefore measures the clear opening you get with the window fully open, not the size of the glass or the frame.
Both numbers have to be met at once. An opening 380 mm by 380 mm is only 0.14 m², far short of the area required. At the minimum 380 mm on one side, the other side has to be about 921 mm (roughly 36 in) to reach 0.35 m².
- The window must open from the inside without the use of tools
- It must hold itself open: a sash that needs propping does not qualify
- If the sash swings toward a window well, it must not cut into the clearance in a way that would restrict escape
- A cover over the window well must also open from the inside without keys, tools or special knowledge
- One qualifying window per floor level with a bedroom is the minimum; a door straight to the outside on that level also satisfies the rule
Which Window Styles Work for Egress?
What matters is how much of the frame becomes open space. Styles differ a great deal on that, so the same rough opening can pass with one style and fail with another.
| Window style | How much opens | Egress notes |
|---|---|---|
| Casement | The whole sash swings clear | Gives the largest clear opening for its size, so it is the usual choice for a small basement opening |
| Slider | One half slides past the other | Only the open half counts, so the window needs to be much wider overall |
| Single or double hung | One sash slides over the other | Only the open half counts, so the window needs to be much taller overall |
| Awning | The sash tilts out from the top | The sash and its hardware can sit in the escape path, and in a window well the open sash must not reduce the clearance |
See how each style operates on our casement, slider and awning window pages.
Replacing a Basement Window: Cost and Permits
Replacing a basement window in its existing opening is priced like any other standard vinyl window: about $1,000–$2,000+ installed with LAB. Awning windows suit basements and bathrooms well for everyday ventilation, including in light rain.
If the existing opening is too small to meet the egress rule, it has to be enlarged. Enlarging, moving or adding an opening is structural work that can need a building permit, and so can creating a new bedroom. Tell us what you are planning at your free in-home visit and we will tell you honestly what the window side of the project involves.
For more detail, read our article on egress window requirements in Ontario, or add your basement windows to the cost calculator.
Egress Window Questions, Answered
Where these facts come from
The numbers on this page are from Article 9.9.10.1 of Division B of Ontario's Building Code (O. Reg. 163/24), as read in a published copy of the Code on November 18, 2026. The regulation is linked below. Codes are amended from time to time, and your municipal building department has the final say on your project.