Call Now: +1 289-802-2994
Ontario Building Code

Egress & Basement Windows in Ontario

The short answer

In Ontario, a bedroom egress window must open, without tools, to a clear area of at least 0.35 m² (about 3.8 sq ft), with no side of that opening smaller than 380 mm (about 15 in).

That is Article 9.9.10.1 of the Ontario Building Code. Every floor level with a bedroom needs at least one such window, unless a door on that level leads directly outside. If the window opens into a window well, the well needs at least 550 mm (about 22 in) of clearance in front of the window.

Ontario egress window requirements at a glance

RequirementOntario Building Code minimum
Clear open area0.35 m² (about 3.8 sq ft), unobstructed
Smallest side of the opening380 mm (about 15 in), height or width
How it opensFrom the inside, without tools, and it must stay open without a prop
Sill heightNo more than 1,000 mm (about 39 in) above the floor; basements are exempt from this limit
Window wellAt least 550 mm (about 22 in) of clearance in front of the window
Sliding windowsThe 380 mm minimum applies to the part that actually opens

From Article 9.9.10.1, Division B of Ontario's Building Code (O. Reg. 163/24). Imperial figures are rounded. Your municipal building department has the final say on your project.

What the Egress Rule Means in Practice

An egress window is an escape route. If a fire blocks the stairs, someone sleeping in a basement or upper bedroom needs a window they can open and climb through. The Code therefore measures the clear opening you get with the window fully open, not the size of the glass or the frame.

Both numbers have to be met at once. An opening 380 mm by 380 mm is only 0.14 m², far short of the area required. At the minimum 380 mm on one side, the other side has to be about 921 mm (roughly 36 in) to reach 0.35 m².

  • The window must open from the inside without the use of tools
  • It must hold itself open: a sash that needs propping does not qualify
  • If the sash swings toward a window well, it must not cut into the clearance in a way that would restrict escape
  • A cover over the window well must also open from the inside without keys, tools or special knowledge
  • One qualifying window per floor level with a bedroom is the minimum; a door straight to the outside on that level also satisfies the rule

Which Window Styles Work for Egress?

What matters is how much of the frame becomes open space. Styles differ a great deal on that, so the same rough opening can pass with one style and fail with another.

Window styleHow much opensEgress notes
CasementThe whole sash swings clearGives the largest clear opening for its size, so it is the usual choice for a small basement opening
SliderOne half slides past the otherOnly the open half counts, so the window needs to be much wider overall
Single or double hungOne sash slides over the otherOnly the open half counts, so the window needs to be much taller overall
AwningThe sash tilts out from the topThe sash and its hardware can sit in the escape path, and in a window well the open sash must not reduce the clearance

See how each style operates on our casement, slider and awning window pages.

Replacing a Basement Window: Cost and Permits

Replacing a basement window in its existing opening is priced like any other standard vinyl window: about $1,000–$2,000+ installed with LAB. Awning windows suit basements and bathrooms well for everyday ventilation, including in light rain.

If the existing opening is too small to meet the egress rule, it has to be enlarged. Enlarging, moving or adding an opening is structural work that can need a building permit, and so can creating a new bedroom. Tell us what you are planning at your free in-home visit and we will tell you honestly what the window side of the project involves.

For more detail, read our article on egress window requirements in Ontario, or add your basement windows to the cost calculator.

Egress Window Questions, Answered

The Ontario Building Code requires an unobstructed open area of at least 0.35 m² (about 3.8 sq ft) with no dimension less than 380 mm (about 15 in). It is the clear opening that is measured, with the window fully open, not the glass or the frame.

Every floor level that contains a bedroom needs at least one window that meets the egress rule, unless a door on the same floor level gives direct access to the outside.

Where an egress window opens into a window well, the Code requires a clearance of at least 550 mm (about 22 in) in front of the window. If the sash swings toward the well, it must not reduce that clearance in a way that would restrict escape.

Yes, 1,000 mm (about 39 in) above the floor, except in basement areas, where the Code sets no sill height limit.

Yes, if the part that opens meets the rule. With a slider only the openable half counts toward the 0.35 m² area and the 380 mm minimum dimension, so the window has to be considerably larger overall than a casement that does the same job.

In the existing opening, a standard vinyl basement window costs about $1,000–$2,000+ installed with LAB. Enlarging the opening to meet the egress rule is structural work that is priced separately and can need a building permit.

Where these facts come from

The numbers on this page are from Article 9.9.10.1 of Division B of Ontario's Building Code (O. Reg. 163/24), as read in a published copy of the Code on November 18, 2026. The regulation is linked below. Codes are amended from time to time, and your municipal building department has the final say on your project.

Planning a Basement Window Project?

We measure your openings and tell you plainly what each one can take. Free in-home quote, with no obligation.